ABB Low Power Variable Speed Drives (0.12 - 37kW)

Small AC drives are viewed in today’s market as components, in the same way as contactors, relays and timers, and as such they should be just as easy to buy, install and use. They should be low cost and reliable enough to be fitted to any size motor and forgotten about.

By 2002, 94% of all AC Drives installed will be in the range covered by component AC drives. There is a huge potential for energy saving in this often ignored area of the drives market. Under 2.2kW, only 3% of motors are controlled by drives, leaving a 97% untapped market and a massive waste of electrical energy.

This range is a globally manufactured low cost, high quality drive providing exactly what the end user requires. They are designed with the user in mind, being straightforward and simple to use, whilst giving you the benefits you would expect from the No.1 supplier of AC drives in Europe.

The smaller drive range supply process is revolutionary. It makes obtaining low power AC drives easier than ever before, offering:

·        Easy selection/ ordering via the 24-hour order line (0115 9813893).

·        Easy payment via Major Credit Cards accepted.

·        East Midlands delivery from stock within 2 hours.

·        Easy to install, simple 6-step instruction/ commissioning sheet.

·        24 Hour, 365 day technical support line from Inverter Drive Systems (0115 9813893) or direct from ABB (0700 22 66 722).

·        Worldwide warranty and support through networks in every country.

The low power range comprises of four products, the ACS100, the ACS140, the ACS160 and the ACS400.

 

Contents:

1. ACS100: 0.12kW to 2.2kW single phase 200-240V AC, 50/60Hz input.

2. ACS140: 0.12kW to 2.2kW single phase 200-240V AC, 50/60Hz input.

3. ACS140: 0.37kW to 2.2kW 3-phase 380-480V AC, 50/60Hz input.

4. ACS160: 0.55kW to 2.2kW 3-phase 380-480V AC, 50/60Hz input, motor-mounted IP65.

5. ACS400: 2.2kW to 37kW 3-phase 380-480V AC, 50/60Hz input.

 

ACS 100: 0.12kW to 2.2kW single phase 200 - 240V AC, 50/60Hz input.

Technical Specification

Mains Connection:

Voltage - 200 to 240VAC single phase, +/- 10%.
Frequency - 48 to 63Hz.
Power Factor - approximately 0.98

Motor Connection:

Voltage - 0 to supply voltage (3-phase).
Frequency - 0 to 300Hz.

Overload capacity - 1.5 x I2N for 1 min in every 10 min, or 1.25 x I2N for 2 min in every 10 min.
(Based on constant torque at max ambient of 40
oC).

Switching frequency - 4kHz standard, 8kHz low noise, 16kHz silent.
Acceleration/ deceleration time - 0.1 to 1800 seconds.

ACS100 in hand.jpg (20927 bytes)

Programmable Control Connections:

Auxiliary Voltage - 12V DC, max 100mA.
One Analogue Input - Voltage 0(2) to 10V or Current 0(4) to 20mA.
No Analogue Output.
Three Digital Inputs - 12V to 24V DC using internal or external supply NPN or PNP.
One Relay Output - Switching voltage 12 to 250V AC or max 30V DC 0.5A, Continuous current of 10mA to 2A.
No serial communications available.

Environmental Limits:

Ambient Temperature - 0 to 40oC at rated output current and standard switching frequency.
Altitude - 0 to 1000 metres at rated output current.
Relative Humidity - lower than 95% (without condensation).
Protection Class - IP20
Paint Colour - RAL 9002
Contamination Levels - No conductive dust, corrosive liquids or gases.

Product Compliance:

Low Voltage Directive, EMC directive, ISO9001 and ISO14001.
CE, UL, ULc and C-Tick approvals.

Options:

A heatsinkless version is available for applications where space is limited.
Extension cable and IP65 kit for control panel door-mounting of drive keypads.
EMC input filters for protection in first environment (domestic locations).
Braking Units and choppers for dynamic motor braking.
Motor and line chokes for long motor cable runs and harmonic attenuation.

Standard Functions:

IR compensation, Coast or Ramp Stop, DC brake, DC Hold, Square or Linear V/F ratio, 'S' ramp Start, 1 preset speed.

Application Macros:

Factory (Used when there is no keypad available).
ABB Standard (Used when a general purpose 2-wire I/O configuration is required).
3-wire (Used when drive is to be controlled using momentary pushbuttons).
Alternate (Used when altering the direction of rotation of a motor through a digital input).

Motor Protection and Fault Features:

Overload Protection, Output Overcurrent, Output Short Circuit, Motor Earth Fault, Supply Failure, Loss of Analogue Input, Keypad Fault, Over Voltage, Under Voltage. The ACS100 has a fault history of one record.

Back to top

 

ACS 140: 0.12kW to 2.2kW single phase 200 - 240V AC, 50/60Hz input.

Technical Specification

Mains Connection:

Voltage - 200 to 240VAC single phase, +/- 10%
Frequency - 48 to 63Hz
Power Factor - approximately 0.98

Motor Connection:

Voltage - 0 to supply voltage (3-phase)
Frequency - 0 to 300Hz

ACS100 photo2.jpg (23857 bytes)

Overload capacity - 1.5 x I2N for 1 min in every 10 min, or 1.25 x I2N for 2 min in every 10 min.
(Based on constant torque at max ambient of 40
oC)

Switching frequency - 4kHz standard, 8kHz low noise, 16kHz silent.
Acceleration/ deceleration time - 0.1 to 1800 seconds

Programmable Control Connections:

Auxiliary Voltage - 12V DC, max 100mA.
Two Analogue Input - Voltage 0(2) to 10V or Current 0(4) to 20mA.
One Analogue Output - 0(4) to 20mA, load less than 500 ohms.
Five Digital Inputs - 12V to 24V DC using internal or external supply NPN or PNP.
Two Relay Output - Switching voltage 12 to 250V AC or max 30V DC 0.5A, Continuous current of 10mA to 2A.
External control serial communications available via modbus protocol.

Environmental Limits:

Ambient Temperature - 0 to 40oC at rated output current and standard switching frequency.
Altitude - 0 to 1000 metres at rated output current.
Relative Humidity - lower than 95% (without condensation).
Protection Class - IP20
Paint Colour - RAL 9002
Contamination Levels - No conductive dust, corrosive liquids or gases.

Product Compliance:

Low Voltage Directive, EMC directive, ISO9001 and ISO14001.
CE, UL, ULc and C-Tick approvals.

Options:

A heatsinkless version is available for applications where space is limited.
Extension cable and IP65 kit for control panel door-mounting of drive keypads.
EMC input filters for protection in first environment (domestic locations).
Braking Units and choppers for dynamic motor braking.
Motor and line chokes for long motor cable runs and harmonic attenuation.
RS 485/232 adapter.
DriveWindow Light easy programming software.
DriveWeb software for monitoring and controlling inverters over the internet or via a WAP phone.

Standard Functions:

Flying Start (catches spinning load), Torque Boost on Start, Premagnetisation of motor on start, IR compensation, Coast or Ramp Stop, DC injection braking, DC Hold, Square or Linear V/F ratio, 'S' ramp Start, 7 preset speeds, 2 Critical Frequency Skips, Slip Compensation.

Application Macros:

Factory (Used when there is no keypad available).
ABB Standard (Used when a general purpose 2-wire I/O configuration is required).
3-wire (Used when drive is to be controlled using momentary pushbuttons).
Alternate (Used when altering the direction of rotation of a motor through a digital input).
Motor Potentiometer (Used when varying the speed via digital signals i.e. through PLC outputs).
Hand/ Auto (Used typically in HVAC and pumping applications with Manual and Automatic PLC control).
PID (Used to create closed-loop control systems using pressure, flow, temperature etc as a reference).
Premagnetise (Used when the the motor has to start very quickly by previously building up the flux in the motor).

Motor Protection and Fault Features:

Overload Protection, Stall Protection, Output Overcurrent, Output Short Circuit, Motor Earth Fault, Supply Failure, Loss of Analogue Input, Keypad Fault, Over Voltage, Under Voltage. The ACS140 has a fault history of three records.

Back to top

 

ACS 140: 0.37kW to 2.2kW 3-phase 380 - 480V AC, 50/60Hz input.

The Technical Specification is as above but with a mains input voltage of 380 - 480V AC.

Also the heatsinkless version is not available.

 

Back to top

 

ACS 160: 0.55kW to 2.2kW 3-phase 380 - 480V AC, 50/60Hz input. (Motor-Mounted)

The ACS160 is an innovative inverter that can be mounted on top of a standard AC motor to produce an integrated motor/ drive package. Alternatively the ACS160 can be wall mounted like a conventional drive and in this case is supplied with an external cooling fan. The motor mounting version comes with a kit that enables the unit to be quickly mounted on the terminal box of most manufacturers standard TEFC type induction motors. This unit utilises the motors cooling arrangement to also cool the inverter.

Main Features

  • Compact and easy to retrofit to existing motors - No additional cabling required.

  • IP65 (NEMA 4) protection with tough Aluminium construction.

  • Supports all major Fieldbuses - Profibus DP, DeviceNet, Interbus-S, LonWorks, CanOpen, Modbus.

  • Built-in brake chopper; control for electromechanical brake.


Technical Specification

Mains Connection:

Voltage - 380 to 500VAC 3-phase, +/- 10%
Frequency - 48 to 63Hz
Power Factor - approximately 0.98

Motor Connection:

Voltage - 0 to supply voltage (3-phase)
Frequency - 0 to 250Hz

Overload capacity - 1.5 x I2N for 1 min in every 10 min, or 1.8 x I2N for 2 seconds (start-up torque).
(Based on constant torque at max ambient of 40
oC).

ACS160.jpg (9528 bytes)

Switching frequency - 4kHz standard, 8kHz low noise
Acceleration/ deceleration time - 0.1 to 1800 seconds

Programmable Control Connections:

Auxiliary Voltage - 24V DC, max 180mA.
Two Analogue Input - Voltage 0(2) to 10V or Current 0(4) to 20mA.
One Analogue Output - 0(4) to 20mA, load less than 500 ohms.
Five Digital Inputs - 12V to 24V DC using internal or external supply NPN or PNP.
Two Relay Output - Switching voltage 12 to 250V AC or max 30V DC 0.5A, Continuous current of 10mA to 2A.
External control through several fieldbus options (See below). Modbus protocol as standard.

Environmental Limits:

Ambient Temperature of -10 to 40oC at rated output current and standard switching frequency.
Altitude - 0 to 1000 metres at rated output current.
Relative Humidity - lower than 95% (without condensation).
Protection Class - IP65
Paint Colour - RAL 9002
Contamination Levels - According to IP65 specification.

Product Compliance:

Low Voltage Directive, EMC directive, ISO9001 and ISO14001.
CE, UL, ULc and C-Tick approvals.

Options:

Pulse encoder direct connection using inverters digital inputs.
IP65 inverter keypad kit c/w 3 metre cable for remote mounting of the inverter keypad.
Units available with built-in 1st environment EMC input filters for domestic locations.
Integrated brake resistors for dynamic motor braking.
Fieldbus gateways for
Profibus DP, DeviceNet, Interbus-S, LonWorks, CanOpen.
RS 485/232 adapter for Modbus which is provided as standard.
DriveWindow Light easy programming software.
DriveWeb software for monitoring and controlling inverters over the internet or via a WAP phone.

Standard Functions:

Flying Start (catches spinning load), Torque Boost on Start, Premagnetisation of motor on start, IR compensation, Coast or Ramp Stop, DC injection braking, DC Hold, Square or Linear V/F ratio, 'S' ramp Start, 7 preset speeds, 2 Critical Frequency Skips.

Application Macros:

Factory (Used when there is no keypad available).
ABB Standard (Used when a general purpose 2-wire I/O configuration is required).
3-wire (Used when drive is to be controlled using momentary pushbuttons).
Alternate (Used when altering the direction of rotation of a motor through a digital input).
Motor Potentiometer (Used when varying the speed via digital signals i.e. through PLC outputs).
Hand/ Auto (Used typically in HVAC and pumping applications with Manual and Automatic PLC control).
PID (Used to create closed-loop control systems using pressure, flow, temperature etc as a reference).
Premagnetise (Used when the the motor has to start very quickly by previously building up the flux in the motor).
Positioning (Used in conjunction with a pulse encoder for accurate servo motor type positioning).

Motor Protection and Fault Features:

Overload Protection, Stall Protection, Output Overcurrent, Output Short Circuit, Motor Earth Fault, Supply Failure, Loss of Analogue Input, Keypad Fault, Over Voltage, Under Voltage, Motor Overtemperature, Serial Comms Error. The ACS160 has a fault history of three records.

Back to top

 

ACS 400: 2.2kW to 37kW 3-phase 380 - 480V AC, 50/60Hz input.

Technical Specification

Mains Connection:

Voltage - 380 to 480VAC 3-phase, +/- 10%.
Frequency - 48 to 63Hz.
Power Factor - approximately 0.98

Motor Connection:

Voltage - 0 to supply voltage (3-phase).
Frequency - 0 to 250Hz.
Overload capacity - 1.5 x I2N for 1 min in every 10 min, or 1.25 x I2N for 2 min in every 10 min.
(Based on constant torque at max ambient of 40
oC).

Switching frequency - 4kHz standard, 8kHz low noise.
Acceleration/ deceleration time - 0.1 to 1800 seconds.

      IP21 enclosure                IP54 enclosure

ACS400.jpg (14870 bytes)        ACS400 IP54.jpg (8488 bytes)

Programmable Control Connections:

Auxiliary Voltage - 24V DC, max 250mA.
Two Analogue Input - Voltage 0(2) to 10V or Current 0(4) to 20mA.
One Analogue Output - 0(4) to 20mA, load less than 500 ohms.
Five Digital Inputs - 12V to 24V DC using internal or external supply NPN or PNP.
Two Relay Output - Switching voltage 12 to 250V AC or max 30V DC 0.5A, Continuous current of 10mA to 2A.
External control serial communications available via modbus protocol.

Environmental Limits:

Ambient Temperature - 0 to 40oC at rated output current and standard switching frequency.
Altitude - 0 to 1000 metres at rated output current.
Relative Humidity - lower than 95% (without condensation).
Protection Class - IP21 or IP54
Paint Colour - RAL 9002
Contamination Levels - No conductive dust, corrosive liquids or gases.

Product Compliance:

Low Voltage Directive, EMC directive, ISO9001 and ISO14001.
CE, UL, ULc and C-Tick approvals.

Options:

Extension cable and IP65 kit for control panel door-mounting of drive keypads.
EMC input filters for protection in first environment (domestic locations).
Braking Units and choppers for dynamic motor braking.
Motor and line chokes for long motor cable runs and harmonic attenuation.
RS 485/232 adapter for Modbus which is provided as standard.
DriveWindow Light easy programming software.
DriveWeb software for monitoring and controlling inverters over the internet or via a WAP phone.
DDCS adapter to connect Fieldbus gateways to
Profibus DP, DeviceNet, Interbus-S, LonWorks, CanOpen, Modbus Plus.

Standard Functions:

Flying Start (catches spinning load), Torque Boost on Start, Premagnetisation of motor on start, IR compensation, Coast or Ramp Stop, DC injection braking, DC Hold, Square or Linear V/F ratio, 'S' ramp Start, 7 preset speeds, 2 Critical Frequency Skips, Slip Compensation.

Application Macros:

Factory (Used when there is no keypad available).
ABB Standard (Used when a general purpose 2-wire I/O configuration is required).
3-wire (Used when drive is to be controlled using momentary pushbuttons).
Alternate (Used when altering the direction of rotation of a motor through a digital input).
Motor Potentiometer (Used when varying the speed via digital signals i.e. through PLC outputs).
Hand/ Auto (Used typically in HVAC and pumping applications with Manual and Automatic PLC control).
PID (Used to create closed-loop control systems using pressure, flow, temperature etc as a reference).
Premagnetise (Used when the the motor has to start very quickly by previously building up the flux in the motor).
PFC - Pump and Fan Control (Used to create closed-loop pressure/flow systems on multi-parallel-motor installations).

Motor Protection and Fault Features:

Overload Protection, Stall Protection, Output Overcurrent, Output Short Circuit, Motor Earth Fault, Underload, Supply Failure, Loss of Analogue Input, Keypad Fault, Over Voltage, Under Voltage. The ACS400 has a fault history of three records.