ABB
Low Power Variable Speed Drives (0.12 - 37kW)
Small AC drives are viewed in
todays market as components, in the same way as contactors, relays and timers, and
as such they should be just as easy to buy, install and use. They should be low cost and
reliable enough to be fitted to any size motor and forgotten about.
By 2002, 94% of all AC Drives
installed will be in the range covered by component AC drives. There is a huge potential
for energy saving in this often ignored area of the drives market. Under 2.2kW, only 3% of
motors are controlled by drives, leaving a 97% untapped market and a massive waste of
electrical energy.
This range is a globally
manufactured low cost, high quality drive providing exactly what the end user requires.
They are designed with the user in mind, being straightforward and simple to use, whilst
giving you the benefits you would expect from the No.1 supplier of AC drives in Europe.
The smaller drive range supply
process is revolutionary. It makes obtaining low power AC drives easier than ever before,
offering:
· Easy selection/
ordering via the 24-hour order line (0115 9813893).
· Easy payment via
Major Credit Cards accepted.
· East Midlands
delivery from stock within 2 hours.
· Easy to install,
simple 6-step instruction/ commissioning sheet.
· 24 Hour, 365 day
technical support line from Inverter Drive Systems (0115 9813893) or direct from ABB (0700
22 66 722).
· Worldwide warranty
and support through networks in every country.
The low power range comprises of
four products, the ACS100, the ACS140, the ACS160 and the ACS400.
Contents:
1. ACS100: 0.12kW to 2.2kW single phase 200-240V AC, 50/60Hz
input.
2. ACS140: 0.12kW to 2.2kW single phase 200-240V AC, 50/60Hz
input.
3. ACS140: 0.37kW to 2.2kW 3-phase 380-480V AC, 50/60Hz input.
4. ACS160: 0.55kW to 2.2kW 3-phase 380-480V AC, 50/60Hz input,
motor-mounted IP65.
5. ACS400: 2.2kW to 37kW 3-phase 380-480V AC, 50/60Hz input.
ACS 100: 0.12kW to 2.2kW single phase 200 -
240V AC, 50/60Hz input.
Technical Specification
Mains Connection:
Voltage - 200 to 240VAC single
phase, +/- 10%.
Frequency - 48 to 63Hz.
Power Factor - approximately 0.98
Motor Connection:
Voltage - 0
to supply voltage (3-phase).
Frequency - 0 to 300Hz.
Overload capacity - 1.5 x I2N
for 1 min in every 10 min, or 1.25 x I2N for 2 min in every 10 min.
(Based on constant torque at max ambient of 40oC).
Switching frequency - 4kHz
standard, 8kHz low noise, 16kHz silent.
Acceleration/ deceleration time - 0.1 to 1800 seconds. |
 |
Programmable Control Connections:
Auxiliary Voltage - 12V DC, max 100mA.
One
Analogue Input - Voltage 0(2) to 10V or Current 0(4) to 20mA.
No Analogue Output.
Three Digital Inputs - 12V to 24V DC using internal or external supply NPN or PNP.
One Relay Output - Switching voltage 12 to 250V AC or max 30V DC 0.5A, Continuous current
of 10mA to 2A.
No serial communications available.
Environmental Limits:
Ambient Temperature - 0 to 40oC at rated output
current and standard switching frequency.
Altitude - 0 to 1000 metres at rated output current.
Relative Humidity - lower than 95% (without condensation).
Protection Class - IP20
Paint Colour - RAL 9002
Contamination Levels - No conductive dust, corrosive liquids or gases.
Product Compliance:
Low Voltage Directive, EMC
directive, ISO9001 and ISO14001.
CE, UL, ULc and C-Tick approvals.
Options:
A heatsinkless version is available
for applications where space is limited.
Extension cable and IP65 kit for control panel door-mounting of drive keypads.
EMC input filters for protection in first environment (domestic locations).
Braking Units and choppers for dynamic motor braking.
Motor and line chokes for long motor cable runs and harmonic attenuation.
Standard Functions:
IR compensation, Coast or Ramp
Stop, DC brake, DC Hold, Square or Linear V/F ratio, 'S' ramp Start, 1 preset speed.
Application Macros:
Factory (Used when there is no
keypad available).
ABB Standard (Used when a general purpose 2-wire I/O configuration is required).
3-wire (Used when drive is to be controlled using momentary pushbuttons).
Alternate (Used when altering the direction of rotation of a motor through a digital
input).
Motor Protection and Fault
Features:
Overload Protection, Output
Overcurrent, Output Short Circuit, Motor Earth Fault, Supply Failure, Loss of Analogue
Input, Keypad Fault, Over Voltage, Under Voltage. The ACS100 has a fault history of one
record.
Back to top
ACS 140: 0.12kW to 2.2kW single phase 200 - 240V
AC, 50/60Hz input.
Technical Specification
Mains Connection:
Voltage - 200 to 240VAC single
phase, +/- 10%
Frequency - 48 to 63Hz
Power Factor - approximately 0.98
Motor Connection:
Voltage - 0
to supply voltage (3-phase)
Frequency - 0 to 300Hz |
 |
Overload capacity - 1.5 x I2N
for 1 min in every 10 min, or 1.25 x I2N for 2 min in every 10 min.
(Based on constant torque at max ambient of 40oC)
Switching frequency - 4kHz
standard, 8kHz low noise, 16kHz silent.
Acceleration/ deceleration time - 0.1 to 1800 seconds
Programmable Control Connections:
Auxiliary Voltage - 12V DC, max 100mA.
Two
Analogue Input - Voltage 0(2) to 10V or Current 0(4) to 20mA.
One Analogue Output - 0(4) to 20mA, load less than 500 ohms.
Five Digital Inputs - 12V to 24V DC using internal or external supply NPN or PNP.
Two Relay Output - Switching voltage 12 to 250V AC or max 30V DC 0.5A, Continuous current
of 10mA to 2A.
External control serial communications available via modbus protocol.
Environmental Limits:
Ambient Temperature - 0 to 40oC at rated output
current and standard switching frequency.
Altitude - 0 to 1000 metres at rated output current.
Relative Humidity - lower than 95% (without condensation).
Protection Class - IP20
Paint Colour - RAL 9002
Contamination Levels - No conductive dust, corrosive liquids or gases.
Product Compliance:
Low Voltage Directive, EMC
directive, ISO9001 and ISO14001.
CE, UL, ULc and C-Tick approvals.
Options:
A heatsinkless version is available
for applications where space is limited.
Extension cable and IP65 kit for control panel door-mounting of drive keypads.
EMC input filters for protection in first environment (domestic locations).
Braking Units and choppers for dynamic motor braking.
Motor and line chokes for long motor cable runs and harmonic attenuation.
RS 485/232 adapter.
DriveWindow Light easy programming software.
DriveWeb software for monitoring and controlling inverters over the internet or via a WAP
phone.
Standard Functions:
Flying Start (catches spinning
load), Torque Boost on Start, Premagnetisation of motor on start, IR compensation, Coast
or Ramp Stop, DC injection braking, DC Hold, Square or Linear V/F ratio, 'S' ramp Start, 7
preset speeds, 2 Critical Frequency Skips, Slip Compensation.
Application Macros:
Factory (Used when there is no
keypad available).
ABB Standard (Used when a general purpose 2-wire I/O configuration is required).
3-wire (Used when drive is to be controlled using momentary pushbuttons).
Alternate (Used when altering the direction of rotation of a motor through a digital
input).
Motor Potentiometer (Used when varying the speed via digital signals i.e. through PLC
outputs).
Hand/ Auto (Used typically in HVAC and pumping applications with Manual and Automatic PLC
control).
PID (Used to create closed-loop control systems using pressure, flow, temperature etc as a
reference).
Premagnetise (Used when the the motor has to start very quickly by previously building up
the flux in the motor).
Motor Protection and Fault
Features:
Overload Protection, Stall
Protection, Output Overcurrent, Output Short Circuit, Motor Earth Fault, Supply Failure,
Loss of Analogue Input, Keypad Fault, Over Voltage, Under Voltage. The ACS140 has a fault
history of three records.
Back to top
ACS 140: 0.37kW to 2.2kW 3-phase 380 - 480V
AC, 50/60Hz input.
The Technical Specification is as
above but with a mains input voltage of 380 - 480V AC.
Also the heatsinkless version is
not available.
Back to top
ACS 160: 0.55kW to 2.2kW 3-phase 380 - 480V
AC, 50/60Hz input. (Motor-Mounted)
The ACS160 is an innovative inverter that can be mounted on top of a
standard AC motor to produce an integrated motor/ drive package. Alternatively the ACS160
can be wall mounted like a conventional drive and in this case is supplied with an
external cooling fan. The motor mounting version comes with a kit that enables the unit to
be quickly mounted on the terminal box of most manufacturers standard TEFC type induction
motors. This unit utilises the motors cooling arrangement to also cool the inverter.
Main Features
Compact and easy to retrofit to existing motors - No additional cabling
required.
IP65 (NEMA 4) protection with tough Aluminium construction.
Supports all major Fieldbuses - Profibus DP, DeviceNet, Interbus-S,
LonWorks, CanOpen, Modbus.
Built-in brake chopper; control for electromechanical brake.
Technical Specification
Mains Connection:
Voltage - 380 to 500VAC 3-phase,
+/- 10%
Frequency - 48 to 63Hz
Power Factor - approximately 0.98
Motor Connection:
Voltage - 0
to supply voltage (3-phase)
Frequency - 0 to 250Hz
Overload capacity - 1.5 x I2N
for 1 min in every 10 min, or 1.8 x I2N for 2 seconds (start-up torque).
(Based on constant torque at max ambient of 40oC). |
 |
Switching frequency - 4kHz
standard, 8kHz low noise
Acceleration/ deceleration time - 0.1 to 1800 seconds
Programmable Control Connections:
Auxiliary Voltage - 24V DC, max 180mA.
Two
Analogue Input - Voltage 0(2) to 10V or Current 0(4) to 20mA.
One Analogue Output - 0(4) to 20mA, load less than 500 ohms.
Five Digital Inputs - 12V to 24V DC using internal or external supply NPN or PNP.
Two Relay Output - Switching voltage 12 to 250V AC or max 30V DC 0.5A, Continuous current
of 10mA to 2A.
External control through several fieldbus options (See below). Modbus protocol as
standard.
Environmental Limits:
Ambient Temperature of -10 to 40oC at rated output
current and standard switching frequency.
Altitude - 0 to 1000 metres at rated output current.
Relative Humidity - lower than 95% (without condensation).
Protection Class - IP65
Paint Colour - RAL 9002
Contamination Levels - According to IP65 specification.
Product Compliance:
Low Voltage Directive, EMC
directive, ISO9001 and ISO14001.
CE, UL, ULc and C-Tick approvals.
Options:
Pulse encoder direct connection
using inverters digital inputs.
IP65 inverter keypad kit c/w 3 metre cable for remote mounting of the inverter keypad.
Units available with built-in 1st environment EMC input filters for domestic locations.
Integrated brake resistors for dynamic motor braking.
Fieldbus gateways for Profibus DP, DeviceNet, Interbus-S,
LonWorks, CanOpen.
RS 485/232 adapter for Modbus which is provided as standard.
DriveWindow Light easy programming software.
DriveWeb software for monitoring and controlling inverters over the internet or via a WAP
phone.
Standard Functions:
Flying Start (catches spinning
load), Torque Boost on Start, Premagnetisation of motor on start, IR compensation, Coast
or Ramp Stop, DC injection braking, DC Hold, Square or Linear V/F ratio, 'S' ramp Start, 7
preset speeds, 2 Critical Frequency Skips.
Application Macros:
Factory (Used when there is no
keypad available).
ABB Standard (Used when a general purpose 2-wire I/O configuration is required).
3-wire (Used when drive is to be controlled using momentary pushbuttons).
Alternate (Used when altering the direction of rotation of a motor through a digital
input).
Motor Potentiometer (Used when varying the speed via digital signals i.e. through PLC
outputs).
Hand/ Auto (Used typically in HVAC and pumping applications with Manual and Automatic PLC
control).
PID (Used to create closed-loop control systems using pressure, flow, temperature etc as a
reference).
Premagnetise (Used when the the motor has to start very quickly by previously building up
the flux in the motor).
Positioning (Used in conjunction with a pulse encoder for accurate servo motor type
positioning).
Motor Protection and Fault
Features:
Overload Protection, Stall
Protection, Output Overcurrent, Output Short Circuit, Motor Earth Fault, Supply Failure,
Loss of Analogue Input, Keypad Fault, Over Voltage, Under Voltage, Motor Overtemperature,
Serial Comms Error. The ACS160 has a fault history of three records.
Back to top
ACS 400: 2.2kW to 37kW 3-phase 380 - 480V AC,
50/60Hz input.
Technical Specification
Mains Connection:
Voltage - 380 to 480VAC 3-phase,
+/- 10%.
Frequency - 48 to 63Hz.
Power Factor - approximately 0.98
Motor Connection:
Voltage - 0
to supply voltage (3-phase).
Frequency - 0 to 250Hz.
Overload capacity - 1.5 x I2N for 1 min in every 10 min, or 1.25 x I2N
for 2 min in every 10 min.
(Based on constant torque at max ambient of 40oC).
Switching frequency - 4kHz standard, 8kHz low noise.
Acceleration/ deceleration time - 0.1 to 1800 seconds. |
IP21 enclosure
IP54
enclosure 
|
Programmable Control Connections:
Auxiliary Voltage - 24V DC, max 250mA.
Two
Analogue Input - Voltage 0(2) to 10V or Current 0(4) to 20mA.
One Analogue Output - 0(4) to 20mA, load less than 500 ohms.
Five Digital Inputs - 12V to 24V DC using internal or external supply NPN or PNP.
Two Relay Output - Switching voltage 12 to 250V AC or max 30V DC 0.5A, Continuous current
of 10mA to 2A.
External control serial communications available via modbus protocol.
Environmental Limits:
Ambient Temperature - 0 to 40oC at rated output
current and standard switching frequency.
Altitude - 0 to 1000 metres at rated output current.
Relative Humidity - lower than 95% (without condensation).
Protection Class - IP21 or IP54
Paint Colour - RAL 9002
Contamination Levels - No conductive dust, corrosive liquids or gases.
Product Compliance:
Low Voltage Directive, EMC
directive, ISO9001 and ISO14001.
CE, UL, ULc and C-Tick approvals.
Options:
Extension cable and IP65 kit for
control panel door-mounting of drive keypads.
EMC input filters for protection in first environment (domestic locations).
Braking Units and choppers for dynamic motor braking.
Motor and line chokes for long motor cable runs and harmonic attenuation.
RS 485/232 adapter for Modbus which is provided as standard.
DriveWindow Light easy programming software.
DriveWeb software for monitoring and controlling inverters over the internet or via a WAP
phone.
DDCS adapter to connect Fieldbus gateways to Profibus DP,
DeviceNet, Interbus-S, LonWorks, CanOpen, Modbus Plus.
Standard Functions:
Flying Start (catches spinning
load), Torque Boost on Start, Premagnetisation of motor on start, IR compensation, Coast
or Ramp Stop, DC injection braking, DC Hold, Square or Linear V/F ratio, 'S' ramp Start, 7
preset speeds, 2 Critical Frequency Skips, Slip Compensation.
Application Macros:
Factory (Used when there is no
keypad available).
ABB Standard (Used when a general purpose 2-wire I/O configuration is required).
3-wire (Used when drive is to be controlled using momentary pushbuttons).
Alternate (Used when altering the direction of rotation of a motor through a digital
input).
Motor Potentiometer (Used when varying the speed via digital signals i.e. through PLC
outputs).
Hand/ Auto (Used typically in HVAC and pumping applications with Manual and Automatic PLC
control).
PID (Used to create closed-loop control systems using pressure, flow, temperature etc as a
reference).
Premagnetise (Used when the the motor has to start very quickly by previously building up
the flux in the motor).
PFC - Pump and Fan Control (Used to create closed-loop pressure/flow systems on
multi-parallel-motor installations).
Motor Protection and Fault
Features:
Overload Protection, Stall
Protection, Output Overcurrent, Output Short Circuit, Motor Earth Fault, Underload, Supply
Failure, Loss of Analogue Input, Keypad Fault, Over Voltage, Under Voltage. The ACS400 has
a fault history of three records.